Fluke CNX 3000 Wireless Multimeter

CNX: Fluke’s Newest System of Wireless Troubleshooting Tools!

Wireless Digital Multimeter

  • Displays live readings from up to 3 modules at a time on its screen, in addition to the DMM reading
  • Communicates with modules from up to 20 m. away
  • Can operate as a traditional DMM

Wireless Modules

  • Available now: AC voltage, AC current and k type temperature modules; more to follow!
  • Record data (min, max, avg)
  • Designed to be left behind for short-term recording or monitoring (8-25 days)
  • Can operate independently of DMM

PC Adapter

  • Enables real-time monitoring of up to 10 modules at a time on a PC with the PC App
  • Enables stored readings to be downloaded

Awesome Benefits!

  • Isolate problems faster by taking up to 10 measurements at the same time, and viewing them all at the same place
  • Spend less time waiting for the measurements you need by logging
  • Minimize writing measurements down by logging and time-stamping
  • Maximize safety and comfort by measuring from up to 20 m. / 66 ft. away
  • Increase your convenience, productivity and safety
  • Minimize downtime, reduce costs

Wide Applications

  • Load studies
  • Production test troubleshooting
  • Power interruption
  • Current imbalance
  • Voltage imbalance
  • Ground fault current
  • Single or multi-phase measurement

Default Kit Includes

  • Fluke CNX 3000 Wireless Multimeter
  • True-RMS Wireless Multimeter
  • TL175 Test Leads
  • AC175 Alligator Clips


It's like being in many places at once!

Watch as FLUKE brings in the clones....LINK

UNIQUE FEATURE: Compatible with Ti125 Thermal imager (coming in SPRING 2013)


Detailed Specficiations

For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).

Detailed Specifications
AC Voltage
Range ¹ Resolution Accuracy ² ³
45 Hz to 500 Hz 500 Hz to 1 kHz
600.0 mV 0.1 mV 1.0 % + 3 2.0 % + 3
6.000 V 0.001 V
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V
¹ All AC voltage ranges are specified from 1 % of range to 100 % of range.
² Crest factor of ≤ 3 at full scale p to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3.

DC Voltage, Continuity, Resistance, Diode Test and Capacitance
Function Range ¹ Resolution Accuracy
mV 600.0 mV 0.1 mV 0.09 % + 2
V 6.000 V 0.001 V 0.09 % + 2
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V 0.15 % + 2
))) 600 Ω 1 Ω Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
600.0 Ω 0.1 Ω 0.5 % + 2
6.000 kΩ 0.001 kΩ 0.5 % + 1
60.00 kΩ 0.01 kΩ
60.00 kΩ 0.1 kΩ
600.0 kΩ 0.001 MΩ
50.00 MΩ 0.01 MΩ 1.5 % + 3
Diode test 2.000 V 0.001 V 1 % + 2
µF 1000 nF 1 nF 1.2 % + 2
10.00 μF 0.01 μF
100.0 μF 0.1 μF
9999 μF ¹ 1 μF 10 %
¹ In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.

AC and DC Current
Function Range ¹ Resolution Accuracy
mA AC
(45 Hz to 1 kHz)
60.00 mA 0.01 mA 1.5 % + 3
400.0 mA ³ 0.1 mA
mA DC ² 60.00 mA 0.01 mA 0.5 % + 3
400.0 mA 0.1 mA
¹ All AC current ranges are specified from 5 % of range to 100 % of range.
² Input burden voltage (typical): 400 mA input 2 mV/mA.
³ 400.0 mA accuracy specified up to 600 mA overload.

Frequency
Range ¹ Resolution Accuracy
99.99 Hz 0.01 Hz 0.1 % + 1
999.9 Hz 0.1 Hz
9.999 kHz 0.001 kHz
99.99 kHz 0.01 kHz
¹ Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.

Input Characteristics
Function Overload
Protection
Input Impedance
(nominal)
Common Mode Rejection Ratio (1 kΩ unbalance) Normal Mode Rejection
1100 V RMS > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
1100 V RMS > 10 MΩ < 100 pF > 60 dB, DC to 60 Hz  
1100 V RMS > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
Open circuit test voltage Full scale Typical short circuit current
To 6 MΩ 50 MΩ
1100 V RMS < 2.7 V DC < 0.7 V DC < 0.9 V DC < 350 mA
1100 V RMS < 2.7 V DC 2.000 V DC < 1.1 mA

Function Overload Protection Overload
mA Fused, 44/100 A, 1000 V FAST Fuse 600 mA overload for 2 minutes maximum, 10 minutes rest minimum

MIN/MAX Recording
Function Accuracy
DC functions The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration
AC functions The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration

General Specifications
Maximum voltage between any terminal and earth ground 1000 V DC or AC RMS
Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD) Update rate: 4/sec
Volts, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts
Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
Battery life 300 hours minimum
Temperature Operating: -10 °C to 50 °C Storage: -40 °C to 60 °C
Relative humidity 0 % to 90 % (0 °C to 35 °C)
0 % to 75 % (35 °C to 40 °C)
0 % to 45 % (40 °C to 50 °C)
Altitude Operating: 2,000 m
Storage: 12,000 m
Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Wireless frequency 2.4 GHz ISM Band 20 meter range
Size (H x W x L) 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
Weight 340 g (12 oz)
Safety standards US ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition
CE European: IEC/EN 61010-1:2010
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) rating IP54


Kit Descriptions

FLK-CNX 3000 Industrial System

  • Multimeter
  • 3 iFlex™ Clamp Modules
  • 1 AC Voltage Module and accessories

FLK-CNX 3000 General Maintenance System

  • Multimeter
  • iFlex™ Clamp Module
  • AC Voltage Module and accessories

FLK-CNX 3000 HVAC System

  • Multimeter
  • AC Current Clamp Module
  • Temperature Module and accessories

FLK-CNX t3000 Kit

  • Multimeter
  • Temperature Module and accessories

Fluke CNX i3000 Kit

  • Multimeter
  • iFlex™ Clamp Module and accessories

Fluke CNX a3000 Kit

  • Multimeter
  • AC Current Clamp Module and Accessories

Fluke CNX v3000 Kit

  • Multimeter
  • AC Voltage Module and accessories

Related Items

Recently Viewed Items

Category