General |
Display: |
LCD (5 inches diagonal) |
Backlight: |
Blue (adjustable duration) |
Over Range Display: |
OL for pressure, - - - - for temperature |
Auto Power Off: |
30 minutes of inactivity (adjustable) |
Maximum Manifold Pressure: |
800 Psig (5500 kPa) |
Battery Type: |
6 x AA alkaline |
Battery Life: |
350 hours typical (without vacuum, backlight, and wireless) |
Radio Frequency: |
2.4 GHz |
Wireless Range: |
350 feet (106 meters) line of sight Distance decreases through obstructions |
Data Port: |
Micro USB (for extracting logged data or updating firmware) |
Operating Environment: |
32°F to 122°F (0°C to 50°C) at <75% RH |
Storage Environment: |
-4°F to 140°F (-20°C to 60°C) at <80% RH (With battery removed) |
Temperature Coefficient: |
0.1 x (specified accuracy) per °C (0°C to 18°C, 28°C to 50°??C) 0.1 x per 1.8°F (32°F to 64°F, 82°F to 122°F) |
Weight: |
4.03 lbs (1.83 kg) |
Water Resistant: |
Designed to IP54 |
Refrigerants: |
R11, R12, R13, R22, R23,, R32, R113, R114, R115, R116, R123, R124, R125, R134A, R236FA, R245FA, R290, R401A, R401B, R402A, R402B, R403B, R404A, R406A, R407A, R407C, R407F, R408A, R409A, R410A, R413A, R414A, R414B, R416A, R417A, R417C, R420A, R421A, R421B, R422A, R422B, R422C, R422D, R424A, R427A R428A R434A R438A R448A R449A R450A R452A, R452B, R453A, R454B, R458A, R500, R501, R502, R503, R507A, R508B, R513A, R600, R600A, R601, R601A, R744, R1233ZD, R1234YF, R1234ZE New refrigerants are continually being added so be sure to visit Fieldpiece.com for the latest firmware |
Pressure |
Sensor Type: |
Absolute pressure sensors |
Port Type: |
(1) 3/8" and (3) 1/4" standard NPT male flare fittings |
Pressure Range and Units: |
580 Psig (English), 40.00 Bar (Metric), 4.000 MPa (Metric), and 4000 kPa (Metric) |
Negative Pressure Range and Units: |
29 inHg (English), 74 cmHg (Metric) |
Resolution: |
0.1 Psig; 0.01 Bar; 0.001 MPa; 1 kPa; 0.1 inHg; 1 cmHg |
Negative Pressure Accuracy: |
29 inHg to O inHg: ±0.2 inHg; 74 cmHg to O cmHg: ± 1 cm Hg |
Pressure Accuracy: |
- 0 Psig to 200 Psig: ± 1 Psig;
- 200 Psig to 580 Psig: ±(0.3% of reading + 1 Psig);
- 0 Bar to 13.78 Bar ±0.07 Bar;
- 13.78 Bar to 40.00 Bar: ±(0.3% of reading+ 0.07 Bar);
- 0 MPa to 1.378 MPa: ±0.007 MPa;
- 1.378 MPa to 4.000 MPa: ±(0.3% of reading+ 0.007 MPa);
- 0 kPa to 1378 kPa: ±7 kPa;
- 1378 kPa to 4000 kPa: ±(0.3% of reading+ 7 kPa
|
Temperature |
Sensor Type: |
Type K thermocouple (nickel chromium/nickel aluminum) |
Jack Type: |
(3) Type K thermocouple |
Range: |
-50°F to 257°F (-46°C to 125°C) limited by the thermocouple specification. Display range is -95°F to 999.9°F (-70°C to 537°C |
Resolution: |
0.1°F (0.1°C) |
Accuracy: |
Shown accuracies are after field calibration. ±(1.0°F) -95°F to 200°F, ±(2.0°F) 200°F to 999.9°F ±(0.5°C) -70°C to 93°C, ±(1.0°C) 93°C to 537.0°C |
Deep Vacuum |
Sensor Type: |
Thermistor |
Port Type: |
(3) 1/4" standard NPT male flare fittings (SM380V) (1) 3/8" and (3) 1/4" standard NPT male flare fittings (SM480V) |
Range and Units: |
- 50 to 9999 microns of mercury (English)
- 6 to 1330 Pascals (Metric)
- 0.06 to 13.3 mBar (Metric)
- 50 to 9999 mTorr (Metric)
- 0.05 to 10 Torr (Metric, equivalent to mmHg) |
Best Resolution: |
- 1 micron of mercury (below 2000 microns)
- 1 Pascal (below 250 Pascals)
- 0.001 mBar (below 2.5 mBar)
- 1 mTorr (below 2000 mTorr)
- 0.001 Torr (below 2.5 Torr) |
Accuracy @ 77°F (25°C): |
±(5% of reading + 5 microns of mercury)
±(5% of reading + 1 Pascal)
±(5% of reading + 0.01 mBarr)
±(5% of reading + 5 mTorr)
±(5% of reading + 0.005 Torr) |