General Specifications |
Display: |
3 3/4 digit liquid crystal display (LCD) with a
maximum reading of 3999. |
Analog bar graph: |
41 segments with measurements 20 times per second. |
Range (RNG): |
Manual ranging mode (HS35) |
Overrange: |
"OL" mark indication. |
Auto power off: |
30 minutes. |
Operating environment: |
32 to 122°F (0 to 50°C) at <70% R.H. |
Storage temperature: |
-4 to 140°F (-20 to 60°C), 0 to 80% R.H. with battery removed. |
Accuracy: |
Specifications good in ambient conditions of 73°F ±9°F (23°C ±5°C), <75% relative humidity |
Temperature coefficient: |
0.1×(specified accuracy) per °F/°C. (32 to 64°F (0 to 18°C), 82 to 122°F(28 to 50°C)). |
Power: |
Single standard 9-volt battery, NEDA 1604,
JIS 006P, IEC 6F22. |
Battery life: |
300 hours typical with alkaline. |
Accessories: |
One pair test leads, one pair alligator clips, k-type thermocouple, 9V battery (installed), and operating instructions. |
Safety: |
UL,CE,Cat III600V,UL61010-1,IEC/EN61010-1. |
Temperature |
Range: |
-30 to 1000°F (-34 to 538°C) |
Resolution: |
0.1°F/°C |
Accuracy: |
±1°F, 32 to 120°F (0 to 49°C) |
±1% + 1.5°F, -4 to 750°F (-20 to 399°C) |
±2% + 4°F, -30 to -4°F (-34 to -20°C) |
±2% + 4°F, 750 to 1000°F (399 to 538°C) |
Sensor type: |
K-type thermocouple |
Overload protection: |
60 VDC or 30 VAC rms |
Continuity |
Audible indication: |
Less than 40Ω |
Response time: |
500ms |
Overload protection: |
500VDC or AC rms |
Green LED will be on continuously. |
DC volts |
Ranges: |
400mV, 4000mV, 40V, 400V, 600V |
Resolution: |
0.1mV |
Accuracy: |
±(0.5% rdg + 2 dgt) |
Input impedance: |
3MΩ on V inputs, 10MΩ on mV input |
Overload protection: |
600VDC or AC rms |
Transient protection: |
6kV for 10μ sec |
AC volts (50Hz - 500Hz) |
Ranges: |
400mV, 4V, 40V, 400V, 600V |
Conversion: |
True RMS (HS36), average (HS35) |
Crest factor: |
Less than or equal to 3 (HS36) |
Resolution: |
0.1mV |
Accuracy: |
±(1.2% rdg + 5 dgts) 50Hz ~ 60Hz on 400mV range |
±(1.5% rdg + 5 dgts) |
±(2% rdg + 5 dgts) on 600V range |
Input impedance: |
3MΩ |
Overload protection: |
600V DC or AC rms |
Transient protection: |
6kV for 10μ sec |
DC current |
Ranges: |
400μA, 4000μA |
Resolution: |
0.1μA |
Accuracy: |
±(1.0% rdg + 2 dgt) |
Voltage burden: |
1V, (8V on 4000μA range) |
Overload protection: |
500V DC or AC rms |
Resistance |
Ranges: |
400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ |
Resolution: |
0.1Ω |
Accuracy: |
±(1.0% rdg + 4 dgts) on 400Ω to 400kΩ ranges |
±(1.5% rdg + 4 dgts) on 4MΩ range |
±(3.0% rdg + 5 dgts) on 40MΩ range |
Open circuit volts: |
-0.45VDC typical, (-1.2VDC on 400Ω range) |
Overload protection: |
500V DC or AC rms |
Capacitance |
Range: |
400μF |
Resolution: |
0.1μF |
Accuracy: |
±(3% rdg + 5 dgts) |
Overload protection: |
500V DC or AC rms |
Frequency |
Ranges: |
4k, 40k, 400k, 4M, 40MHz |
Resolution: |
1Hz |
Accuracy: |
±(0.1% rdg + 3 dgts) |
Sensitivity: |
10Hz ~ 4MHz: > 1Vrms, 4MHz ~ 40MHz: > 2Vrms, <5Vrms |
Minimum pulse width: |
> 25ns |
Duty cycle limits: |
> 30% and < 70% |
Overload protection: |
500V DC or AC rms |