Description
UEi DL589COMBO Clamp Meter Kit with 2 ATTPC4 Temp Clamps, True-RMS, DC Amps, and Diff. Temp
Measure capacitance, voltage, circuit continuity, resistance, temperature. Check system boards and live wires.
The DL589 is an TRMS HVAC/R Clamp Meter It has functions like AC/DC voltage, AC/DC amps, AC/DC microamps, resistance, capacitance, frequency and duty cycle. CATIV rated silicone test leads, back probe leads for mini-split applications, a pair of alligator clips, two thermocouples, 2 ATTPC4, a zippered pouch, backed by a 2-Year warranty.
The ATTPC4 is designed for pipes with a diameter between 3/16 in. and 1 7/16 in. It features a 4.4 ft. cable and uses a mini-K-type connector plug.
Key Features & Benefits
- TRMS
- Backlit Dual Display and Worklight
- Min/Max/Avg/Hold
- Peak Hold
- Auto Volts & Amp selection
- Built-in Magnet w/ hanging strap
- Test Lead Storage
- Visible high-voltage alert
- Easy access battery cover latches
- Over-molded grip
- Auto and Manual ranging
- Input Jack Lock
- Auto calibration
- Auto Power Off
- Low Battery Indicator
- 2-Year limited warranty
- 600A AC/DC
- 1000V DC
- 750V AC
- 2000µA AC/DC
- 60MΩ Resistance
- Capacitance: 2000µF
- Differential Temperature: -328° to 2462°F
- Frequency/Duty Cycle
- Audible Continuity
- Diode Test
- Non-Contact Voltage Detection
- LRA Inrush
- Low Z (impedance)
Applications
- Measure capacitance, voltage, microamps, circuit continuity, resistance, and temperature via K-Type thermocouples. Circuits in Molex plugs, and diode malfunctions
- Flame sensing
- Check system boards and live wires
Specs
| AC Amps Measurement - Jaw input | |||
|---|---|---|---|
| Range | Resolution | Accuracy | Overload Protection |
| 60.00A | 0.01A | ±2.0% +8dgts | 600V RMS |
| 600.0A | 0.1A | ||
| 45 to 400Hz TRMS, Minimum Current for Clamp Measurement 0.3A | |||
| DC Amps Measurement - Jaw input | |||
| Range | Resolution | Accuracy | Overload Protection |
| 60.00A | 0.01A | ±2.0% +8dgts | 600V RMS |
| 600.0A | 0.1A | ||
| Minimum Current for Clamp Measurement 0.2A | |||
| AC Microamps Measurement -Test lead input | |||
| Range | Resolution | Accuracy | Overload Protection |
| 600.0µA | 0.1µA | ±1.5% +3dgts | 600V RMS |
| 2000µA | 1µA | ||
| 45Hz to 400Hz True RMS | |||
| DC Microamps Measurement - Test lead input | |||
| Range | Resolution | Accuracy | Overload Protection |
| 600.00µA | 0.1µA | ±1.5% +2dgts | 600V RMS |
| 2000µA | 1µA | ||
| AC Volts Measurement | |||
| Range | Resolution | Accuracy | Overload Protection |
| 600.0mV | 0.1mV | ±1.0% +3dgts | 1000V RMS |
| 6.000V | 0.001V | ||
| 60.00V | 0.01V | ||
| 600.0V | 0.1V | ||
| 750V | 1V | ||
| 45Hz to 400Hz True RMS | |||
| DC Volts Measurement | |||
| Range | Resolution | Accuracy | Overload Protection |
| 600.0mV | 0.1mV | ±0.5% +4dgts | 1000V RMS |
| 6.000V | 0.001V | ||
| 60.00V | 0.01V | ||
| 600.0V | 0.1V | ||
| 1000V | 1V | ±0.8% +5dgts | |
| Ohms Measurement | |||
| Range | Resolution | Accuracy | Overload Protection |
| 600.0Ω | 0.1Ω | ±0.8% +3dgts | 600V RMS |
| 6.000kΩ | 0.001kΩ | ||
| 60.00kΩ | 0.01kΩ | ||
| 600.0kΩ | 0.1kΩ | ||
| 6.000MΩ | 0.001MΩ | ||
| 60.00MΩ | 0.01MΩ | ±1.2% +3dgts | |
| Diode Test | |||
| Range | Open Circuit Voltage | Test Current (Typical) | Overload Protection |
| 3.0V | < 3.2V DC | 0.25mA | 600V RMS |
| Capacitance Measurement | |||
| Range | Resolution | Accuracy | Overload Protection |
| 10.00nF | 0.01nF | 3.0% +5dgts | 600V RMS |
| 100.0nF | 0.1nF | ||
| 1.000µF | 0.001µF | ||
| 10.00µF | 0.01µF | ||
| 100.0µF | 0.1µF | ||
| 2000µF | 1µF | ||
| Temperature Measurement | |||
| Range | Resolution | Accuracy | Overload Protection |
| -328° to 999°F | 0.1°F | ±(1.0% +3.6°F) | 30V RMS |
| -200° to 999°C | 0.1°C | ±(1.0% +2.0°C) | |
| 1000° to 2462°F | 1°F | ±(1.0% +3°F) | |
| 1000° to 1350°C | 1°C | ±(1.0% +2°C) | |
| Frequency Measurement - Test lead input | |||
| Range | Resolution | Accuracy | Overload Protection |
| 99.99Hz | 0.01Hz | 0.1% +3dgts | 1000V RMS |
| 999.9Hz | 0.1Hz | ||
| 9.999kHz | 0.001kHz | ||
| 99.99kHz | 0.01kHz | ||
| Duty Cycle | |||
| Range | Accuracy | Overload Protection | |
| 1.0 to 99.0% | ±(2.0% per kHz +0.1% +5 dgts) | 1000V RMS | |
| Audible Continuity Measurement | |||
| Open Circuit Voltage < 1.0V | Overload Protection | ||
| Threshold Approx : < 40Ω | 600V RMS | ||
Includes
- (1) UEi DL589 True RMS Clamp Meter
- (2) Temp Clamp (ATTPC4)
- (1) Silicone Test Leads (ATL58)
- (2) Temp Probe (ATT29)
- (1) Alligator Clips (AAC3)
- (2) Back Probes (APB3)
- (4) Batteries (AAA)
- (1) Zippered Pouch
- (1) Manual